fix(ci): align test CPU request with ArgoCD
This commit is contained in:
@@ -35,7 +35,7 @@ jobs:
|
||||
echo "${{ secrets.KUBECONFIG }}" > ~/.kube/config
|
||||
chmod 600 ~/.kube/config
|
||||
kubectl set resources statefulset/im-server -n im-server-system -c im-server \
|
||||
--requests=cpu=1,memory=512Mi --limits=cpu=2,memory=1Gi
|
||||
--requests=cpu=2,memory=512Mi --limits=cpu=2,memory=1Gi
|
||||
kubectl set env statefulset/im-server -n im-server-system -c im-server \
|
||||
CLUSTER_PROXY_TO_MASTER_BUFFER=4096 \
|
||||
CLUSTER_PROXY_TO_MASTER_WORKERS=16 \
|
||||
@@ -108,7 +108,7 @@ jobs:
|
||||
mysql_conn_max_lifetime="$(kubectl get statefulset/im-server -n im-server-system -o \
|
||||
jsonpath='{.spec.template.spec.containers[?(@.name=="im-server")].env[?(@.name=="MYSQL_CONN_MAX_LIFETIME_SECONDS")].value}')"
|
||||
echo "effective requests=${request_cpu}/${request_memory} limits=${limit_cpu}/${limit_memory} liveness=${liveness} mysql=${mysql_max_open}/${mysql_max_idle} registry=${mysql_registry_max_open}/${mysql_registry_max_idle} lifetime=${mysql_conn_max_lifetime}"
|
||||
if [ "${request_cpu}" != "1" ] || [ "${request_memory}" != "512Mi" ] || \
|
||||
if [ "${request_cpu}" != "2" ] || [ "${request_memory}" != "512Mi" ] || \
|
||||
[ "${limit_cpu}" != "2" ] || [ "${limit_memory}" != "1Gi" ] || \
|
||||
[ "${liveness}" != "/livez" ] || [ "${mysql_max_open}" != "24" ] || \
|
||||
[ "${mysql_max_idle}" != "8" ] || [ "${mysql_registry_max_open}" != "4" ] || \
|
||||
|
||||
@@ -31,10 +31,11 @@ kubectl auth can-i list pods.metrics.k8s.io \
|
||||
-n im-server-system
|
||||
```
|
||||
|
||||
Expected values are requests `1 CPU / 512Mi`, limits `2 CPU / 1Gi`, and
|
||||
Expected values are requests `2 CPU / 512Mi`, limits `2 CPU / 1Gi`, and
|
||||
liveness path `/livez`. The MySQL pool environment must be
|
||||
`MYSQL_MAX_OPEN_CONNS=24`, `MYSQL_MAX_IDLE_CONNS=8`,
|
||||
`MYSQL_REGISTRY_MAX_OPEN_CONNS=4`, and `MYSQL_REGISTRY_MAX_IDLE_CONNS=2`.
|
||||
The MySQL connection lifetime must be `MYSQL_CONN_MAX_LIFETIME_SECONDS=1800`.
|
||||
The WebSocket heartbeat environment must be `WS_PING_PERIOD_SECONDS=15` and
|
||||
`WS_PONG_WAIT_SECONDS=90`.
|
||||
The Pod DNS options must be `ndots:1`, `timeout:2`, and `attempts:2`. Keeping
|
||||
|
||||
@@ -46,9 +46,11 @@ spec:
|
||||
value: "4"
|
||||
- name: MYSQL_REGISTRY_MAX_IDLE_CONNS
|
||||
value: "2"
|
||||
- name: MYSQL_CONN_MAX_LIFETIME_SECONDS
|
||||
value: "1800"
|
||||
resources:
|
||||
requests:
|
||||
cpu: "1"
|
||||
cpu: "2"
|
||||
memory: 512Mi
|
||||
limits:
|
||||
cpu: "2"
|
||||
|
||||
Reference in New Issue
Block a user